S­IDNs

S­x­0372 Drive Halt acceleration bipolar

This parameter specifies the deceleration with which the drive is decelerated to the state "Drive Halt" after a
change in the drive state machine. See "Axis State Machine".

Name

Value

Format

dec

Data length

32

Decimal point

2

Min value

0.52

Max value

10 737 418.24

Default value

6283.18

Unit

rad/s

2

Changeable in EtherCAT state

PreOp, SafeOp, Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Note

Parameter set switchover is possible!

This IDN exists as S­0­0372; S­1­0372; S­2­0372; S­3­0372; S­4­00372; S­5­0372; 
S­6­0372 and S­7­0372. Ex factory, all values are identical.

Note

IDNs involved

S‐0‐0134 [

}

 106], S‐0‐0160 [

}

 118]S‐0‐0161 [

}

 119], S‐0‐0162 [

}

 120]