Sx0372 Drive Halt acceleration bipolar
This parameter specifies the deceleration with which the drive is decelerated to the state "Drive Halt" after a
change in the drive state machine. See "Axis State Machine".
Name
Value
Format
dec
Data length
32
Decimal point
2
Min value
0.52
Max value
10 737 418.24
Default value
6283.18
Unit
rad/s
2
Changeable in EtherCAT state
PreOp, SafeOp, Op
Cyclic transfer
No
Device parameter
No
Related to interface revision
No
Note
Parameter set switchover is possible!
This IDN exists as S00372; S10372; S20372; S30372; S400372; S50372;
S60372 and S70372. Ex factory, all values are identical.