S-0-0086 torque/force data scaling type, S‐0‐0086, 66], p­0­0092 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 66

Advertising
background image

S­IDNs

S­0­0086 Torque/force data scaling type

This parameter can be used to select different scaling types for the torque/force data. The drive represents
associated parameters at the selected scale. AX5000 always uses percentage scaling (bit 0).

Attributes

Name

Value

Format

binary

Data length

16

Decimal point

0

Min value

0

Max value

0

Default value

0

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Bit pattern:

Bit Meaning

0­2 Scaling method

Scaling method

0 = percentage
1 = reserved
2 = reserved

3

Scaling type
Scaling type

0 = preferred scaling 
1 = parameter scaling

4

Units for linear / rotational scaling
Units for linear / rotational scaling

0 = Newton [N] or Newton metre [Nm]
1 = reserved

5

Reserved

6

Data reference
Data reference

0 = at the motor shaft
1 = at the load

7 ­

15

Reserved

Note

IDNs involved

S‐0‐0103 [

}

 76]S‐0‐0079 [

}

 57]

AX5000 ­ IDN­Descriptions

66