S00086 Torque/force data scaling type
This parameter can be used to select different scaling types for the torque/force data. The drive represents
associated parameters at the selected scale. AX5000 always uses percentage scaling (bit 0).
Attributes
Name
Value
Format
binary
Data length
16
Decimal point
0
Min value
0
Max value
0
Default value
0
Unit
Changeable in EtherCAT state
No
Cyclic transfer
No
Device parameter
No
Related to interface revision
No
Bit pattern:
Bit Meaning
02 Scaling method
Scaling method
0 = percentage
1 = reserved
2 = reserved
3
Scaling type
Scaling type
0 = preferred scaling
1 = parameter scaling
4
Units for linear / rotational scaling
Units for linear / rotational scaling
0 = Newton [N] or Newton metre [Nm]
1 = reserved
5
Reserved
6
Data reference
Data reference
0 = at the motor shaft
1 = at the load
7
15
Reserved
Note
IDNs involved
AX5000 IDNDescriptions
66