S-0-0273 maximum drive off delay time, S­0­0273 maximum drive off delay time – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 148

Advertising
background image

S­IDNs

S­0­0273 Maximum drive off delay time

This parameter specifies the maximum time interval that is made available to the motor for coming to a halt
after the controller has been disabled (bit 15 of S­0­0134).

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

0

Min value

0

Max value

100 000

Default value

10 000

Unit

ms

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

If the motor has not stopped after this time (v < v_standstill window), the motor is switched torque­free
regardless of the current speed, and the holding brake (if present) is engaged, since an axis malfunction
must be assumed.

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDNs involved

S‐0‐0134 [

}

 106], S‐0‐0207 [

}

 139]

AX5000 ­ IDN­Descriptions

148

Version 3.1

Advertising