S­IDNs

S­0­0024 Configuration list of MDT

The parameter contains the list of parameters for which data are transferred cyclically in the master data
telegram (MDT) from the controller to the drive.

Attributes

Name

Value

Format

idn

Data length

224

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

The AX5000 allows the telegram type "application telegram" in S­0­0015 and therefore supports this list.
Only data that are listed under S­0­0188 are permitted as cyclic data in the MDT.

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDNs involved

S‐0‐0015 [

}

 17]S‐0‐0188 [

}

 130]

Actual length

S­0­0024­Configuration list of MDT / Actual length

Format

Size in bit

Offset

Properties

UINT

16

0

­­­

Max length

S­0­0024­Configuration list of MDT / Max length

Format

Size in bit

Offset

Properties

UINT

16

16

­­­

Configured MDT IDNs

S­0­0024­Configuration list of MDT / Configured MDT IDNs

AX5000 ­ IDN­Descriptions

27

Version 3.1