S-0-0170 probing cycle procedure command (pc) – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 124

Advertising
background image

S­IDNs

S­0­0170 Probing cycle procedure command (pc)

The parameter contains the command measuring probe cycle. If the master sets and activates this
command, the drive responds to S­0­0405, as specified in S­0­0169. The "probe unit" is activated.

Attributes

Name

Value

Format

binary

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

SafeOp, Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

If S­0­0170 is activated, the controller can start numerous measurements. This command should be stopped
as soon as the controller has completed the measurements.

Bit pattern:

Bit Meaning

0

Cancel cmd
Cancel command

0 = disable
1 = enable

1

Set cmd
Set command

0 = disable
1 = enable

2

Reserved

3

Set & enable command
Set & enable command

0 = disable
1 = enable

4

­15

Reserved

Note

IDNs involved

S‐0‐0169 [

}

 122], S‐0‐0405 [

}

 173]

AX5000 ­ IDN­Descriptions

124

Version 3.1

Advertising