S-x-0429 emergency stop deceleration, S­x­0429 emergency stop deceleration – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 178

Advertising
background image

S­IDNs

S­x­0429 Emergency stop deceleration

The parameter contains the deceleration with which the axis is decelerated in case of an error, which triggers
the error response "Closed Loop Ramp".

Name

Value

Format

dec

Data length

32

Decimal point

2

Min value

0.52

Max value

10737418.24

Default value

6283.18

Unit

rad/s

2

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Note

Parameter set switchover is possible!

This IDN exists as S­0­0429; S­1­0429; S­2­0429; S­3­0429; S­4­0429; S­5­0429; 
S­6­0429 and S­7­0429. Ex factory, all values are identical.

Note

IDNs involved

S‐0‐0134 [

}

 106], S‐0‐0160 [

}

 118]S‐0‐0161 [

}

 119], S‐0‐0162 [

}

 120]

AX5000 ­ IDN­Descriptions

178

Version 3.1