S­IDNs

S­0­0037 Additive velocity command value

The parameter contains the additive velocity command value, which is cyclically added to S­0­0036, if the
controller provides the value.

Attributes

Name

Value

Format

dec

Data length

32

Decimal point

0

Min value

­2 147 483 648

Max value

2 147 483 647

Default value

­

Unit

rev/(2

30

 ms)

Changeable in EtherCAT state

No

Cyclic transfer

MDT

Device parameter

No

Related to interface revision

No

The parameter is relevant for velocity­ and position­controlled modes; for scaling see S­0­0036. If the drive is
operated in the position interface, a velocity pre­control can be applied by the controller here.