S-0-0207 drive off delay time, S‐0‐0207 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 139

Advertising
background image

S­IDNs

S­0­0207 Drive off delay time

The parameter contains the delay “Drive off delay time”.

Attributes

Name

Value

Format

udec

Data length

16

Decimal point

0

Min value

0

Max value

10 000

Default value

150

Unit

ms

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

The motor brake management requires this time to engage the motor brake before the controller (and
therefore a torque that may be present) is switched off. 
As soon as bit 15 of S­0­0134 was reset, engaging of the motor holding brake is initiated if either “Maximum
drive off delay time” (S­0­0273) has run off or if “n_min” (S­0­0124) has been underrun.

As soon as “n_min”(S­0­0124) has been underrun, “drive off delay time” (S­0­0207) starts. The control
remains active until “the drive off delay time” has elapsed.

Note

IDNs involved

S‐0‐0011 [

}

 12]S‐0‐0134 [

}

 106], S‐0‐0124 [

}

 102], S­0­0273

Also see about this

2 S­0­0273 Maximum drive off delay time [

}

 148]

AX5000 ­ IDN­Descriptions