S­IDNs

S­0­0903 Configuration list of dynamic AT

The parameter contains a list of IDNs, which are transferred in the dynamic drive telegram (dynamic DT)
from the drive to the controller. Only IDNs listed in S‐0‐0905 are permitted as cyclic data in the dynamic drive
telegram (dynamic DT).

Attributes

Name

Value

Format

IDN

Data length

1088

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

PreOp, SafeOp and Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

from 204

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDN’s involved

S‐0‐0905 [

}

 185]

Actual length

S­0­0903­Configuration list of dynamic AT / Actual length

Format

Size in bits

Offset

UINT

16

0

Max length

S­0­0903­Configuration list of dynamic AT / Max length

Format

Size in bits

Offset

UINT

16

16

Configured AT IDNs

S­0­0903­Configuration list of dynamic AT / Configured AT IDNs

Format

Size in bits

Offset

1056

32