S­IDNs

S­x­0082 Positive torque limit value

The parameter limits the set torque/force value of the drive. It defines the positive upper limit. If this limit is
exceeded, the drive sets bit 3 of S­0­0013. The base for the percentage figure is P­0­0092.

Attributes

Name

Value

Format

udec

Data length

16

Decimal point

1

Min value

0.0

Max value

100.0

Default value

100.0

Unit

%

Changeable in EtherCAT state

PreOp, SafeOp, Op

Cyclic transfer

MDT

Device parameter

No

Related to interface revision

No

Note

Parameter set switchover is possible!

This IDN exists as S­0­0082; S­1­0082; S­2­0082; S­3­0082;
S­4­0082; S­5­0082; S­6­0082, and S­7­0082. Ex factory, all values are identical.

Note

IDNs involved

S‐0‐0086 [

}

 66]S‐0‐0013 [

}

 16]

Note

Additional functional description

AX5000 / parameter set switchover