S-0-0085 torque polarity parameter, S‐0‐0085 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 65

Advertising
background image

S­IDNs

S­0­0085 Torque polarity parameter

The parameter can be used to invert the polarity of torque/force data.

Attributes

Name

Value

Format

Binary

Data length

16

Decimal point

0

Min value

0

Max value

0x0007

Default value

­

Unit

­

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

The polarities are switched externally at the input and output of the closed control loop. Viewed from the
front, the motor shaft rotates in a clockwise direction, if there is a positive torque/force difference and there is
no inversion.

Bit pattern:

Bit Meaning

0

Torque command value
Torque command value

0 = not inverted
1 = inverted

1

Additive torque command value
Additive torque command value

0 = not inverted
1 = inverted

2

Torque feedback value
Torque feedback value

0 = not inverted
1 = inverted

3

­15

Reserved

Note

IDNs involved

S‐0‐0080 [

}

 58]S‐0‐0081 [

}

 59] und S‐0‐0084 [

}

 64]

AX5000 ­ IDN­Descriptions

65

Version 3.1

Advertising