S-0-0907 control word dynamic mdt, Output cycle counter, Rsvd – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 187

Advertising
background image

S­IDNs

S­0­0907 Control word dynamic MDT

The parameter contains the control word for the dynamic master data telegram (dynamic MDT).

Attributes

Name

Value

Format

BINARY

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

In PreOp, SafeOp and Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

from 204

This control word can be transferred to the drive in the dynamic master data telegram. This control word
enables the drive to detect telegram failures.

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Output cycle counter

S­0­0907­Control word dynamic MDT / Output cycle counter

Bit pattern:

Bit Meaning

0­1 Output cycle counter

This counter should be incremented by the controller in each communication cycle.

2­15 Reserved

Format

Size in bits

Offset

UINT2

2

0

rsvd

S­0­0907­Control word dynamic MDT / rsvd

Format

Size in bits

Offset

UINT14

14

2

AX5000 ­ IDN­Descriptions

187

Version 3.1