S­IDNs

S­x­0136 Positive acceleration limit value

The parameter limits the maximum drive acceleration to the specified value. The acceleration is positive if
the magnitude of the velocity increases.

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

2

Min value

0.52

Max value

10737418.24

Default value

6283.18

Unit

rad/s

2

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

This parameter influences the axis control in all position­ and velocity­controlled operating modes. The
dynamics of the control­side set value specification should be lower than the limit configured here, because
otherwise the axis cannot follow the specified acceleration, resulting in discrepancies between the set and
actual positions (following error).

Note

Parameter set switchover is possible!

This IDN exists as S­0­0136; S­1­0136; S­2­0136; S­3­0136; S­4­0136; S­5­0136; S­6­0136
and S­7­0136. Ex factory, all values are identical.

Note

IDNs involved

S‐0‐0160 [

}

 118], S‐0‐0161 [

}

 119]S‐0‐0162 [

}

 120]