S-0-0103 modulo value, S‐0‐0103 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 76

Advertising
background image

S­IDNs

S­0­0103 Modulo Value

This parameter contains the modulo value. If the modulo format is selected in bit 7 of S­0­0076, this
parameter defines the modulo interval. If the modulo format is active, the values of the position interface are
within the interval [0…S­0­0103­1].

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

0

Min value

1

Max value

2147483647

Default value

1048576

Unit

inc

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

For continuously moving axes, the modulo function is used to log the position within a machine cycle. The
modulo function of the AX5000 replaces complex controller programming with a simple parameterisation.

Note

IDNs involved

S‐0‐0047 [

}

 50]S‐0‐0048 [

}

 51], S‐0‐0051 [

}

 52], S‐0‐0076 [

}

 55], S‐0‐0079 [

}

 57],

S‐0‐0091 [

}

 67], S­0­0554, P­0­0010, P­0­0159, 

P­0­0270, P­0­0277, P­0­0279

Note

Additional functional description

AX5000 / Modulo