S­IDNs

S­0­0405 Probe 1 enable

This parameter is used to activate probe unit 1 of the drive. This parameter can be linked with a real­time
control bit (S­0­0301), so that activation is possible via the MasterControlWord (S­0­0134).

Attributes

Name

Value

Format

binary

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

PreOp, SafeOp, Op

Cyclic transfer

MDT

Device parameter

No

Related to interface revision

No

The drive checks this parameter as long as S­0­0170 is enabled. To start a new measuring probe cycle, the
value of this IDN must be changed from 0 to 1.

Bit pattern:

Bit

Meaning

0

Probe 1
Probe 1
0 = not enabled
1 = enabled

1 – 15 Reserved

Note

IDNs involved

S­0130, S‐0131 [

}

 105], S‐0‐0170 [

}

 124], S‐0‐0301 [

}

 154], S­0­0303

Note

Additional functional description

AX5000 / Probe Unit

Also see about this

2 S­0­0130 Probe value 1 positive edge [

}

 104]

2 S­0­0303 Allocation of real­time control bit 2 [

}

 155]

AX5000 ­ IDN­Descriptions

173