S­0­0134 Master control word

The parameter contains the master control word. This parameter is cyclically transferred in each
communication cycle from the controller to the drive. It contains the set operating mode (bits 8, 9, 11), Halt
Drive (bit 13) and controller enable (bit 14).

Attributes

Name

Value

Format

Binary

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

MDT

Device parameter

No

Related to interface revision

No

The controller selects the operation mode via the 3 "operation mode" bits 8, 9, 11 of S­0­0134. If operating
mode 0 is selected here, the drive activates the operating mode selected in the IDN "PrimaryOperationMode"
S­0­0032. If 1 is sent by the controller, the "first secondary mode" is activated, see S­0­0033.

Bit pattern:

Bit Meaning

0 ­5 Reserved

6 Real time control bit 1

Real time control bit 1

7 Real time control bit 2

Real time control bit 2

8­9 Operation mode low

Operation mode low
0 = mode 0 or 4, depending on bit 11 
1 = mode 1 or 5, depending on bit 11 
2 = mode 2 or 6, depending on bit 11 
3 = mode 3 or 7, depending on bit 11

10 Control unit synchronisation bit

Control unit synchronisation bit IPOSYNC toggles with cycle time tNcyc and is used to synchronise the
interpolation.

11 Operation mode high

Operation mode high 
0 = mode 0 to 3
1 = mode 4 to 7

12 Reserved

13 Halt/ restart drive 

Halt Drive/ Restart Drive 
0 = Halt Drive
1 = Restart Drive

14 Enable drive 

Enable drive
0 = Drive not enabled
1 = enable Drive

AX5000 ­ IDN­Descriptions