S-x-0109 motor peak current, S­x­0109 motor peak current – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 80

Advertising
background image

S­IDNs

S­x­0109 Motor peak current

This parameter contains the RMS value of the motor peak current. If the motor peak current is lower than the
available peak current of the servo drive, the current of the servo drive is automatically limited to the value of
this parameter.

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

3

Min value

­

Max value

­

Default value

­

Unit

A

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Note

Parameter set switchover is possible!

This IDN exists as S­0­0109; S­1­0109; S­2­0109; S­3­0109; S­4­0109; S­5­0109; S­6­0109
and S­7­0109. Ex factory, all values are identical.

AX5000 ­ IDN­Descriptions

80

Version 3.1

Advertising