S­IDNs

S­0­0384 Amplifier temperature

The parameter contains the amplifier temperature (actual value). If the warning threshold (S­0­0200) is
exceeded, bit 2 is set by S­0­0012 (C2D). If the error threshold (S­0­0203) is exceeded, the drive is shut
down with an error (C1D).

Attributes

Name

Value

Format

udec

Data length

16

Decimal point

1

Min value

­

Max value

­

Default value

­

Unit

°C

Changeable in EtherCAT state

No

Cyclic transfer

AT

Device parameter

No

Related to interface revision

No

Note

IDNs involved

S‐0‐0011 [

}

 12]S‐0‐0012 [

}

 14], S‐0‐0200 [

}

 136], S‐0‐0203 [

}

 136]

Also see about this

2 S­0­0200 Amplifier warning temperature [

}

 134]

AX5000 ­ IDN­Descriptions