S-0-0219 idn-list of parameter set, Actual length, Max length – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 142: All operation data

Advertising
background image

S­IDNs

S­0­0219 IDN­list of parameter set

The parameter contains a list of parameters for which parameter set switchover is possible. For the
parameters S­0­xxxx and P­0­xxxx listed in this list, data sets 1 to 7 are also supported, i.e. the parameters
S­y­xxxx and P­y­xxxx with y = 1 to 7.

Attributes

Name

Value

Format

idn

Data length

12064

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDNs involved

S‐0‐0216 [

}

 140]

Actual length

S­0­0219­IDN­list of configurable data in the AT / Actual length

Format

Size in bit

Offset

Properties

UINT

16

0

­­­

Max length

S­0­0219­IDN­list of parameter set / Max length

Format

Size in bit

Offset

Properties

UINT

16

16

­­­

All operation data

S­0­0219­IDN­list of parameter set / 

Format

Size in bit

Offset

Properties

12032

32

­­­

AX5000 ­ IDN­Descriptions

142