S-0-0409 probe 1 positive latched (counter), Single mode – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 174

Advertising
background image

S­IDNs

S­0­0409 Probe 1 positive latched (Counter)

This parameter indicates whether a positive edge occurred at Probe 1.

Attributes

Name

Value

Format

binary

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

AT

Device parameter

No

Related to interface revision

No

An IDN can be assigned to this parameter. This parameter can be assigned to a real­time status bit via
S­0­0305. The drive only sets bit 0 of this parameter if the command S­0­0170 is enabled, S­0­0405 is set to
1, and the positive edge of S­0­0401 is enabled. 
If a positive edge occurs at the input, the drive saves the parameterised source value in S­0­0130. The drive
resets this bit, if the controller cancels the command S­0­0170, or if S­0­0405 is reset to 0. 

Bit pattern:

Bit

Meaning

0

Probe 1
Probe 1

0 = not enabled
1 = enabled

1 – 15 Reserved

Note

IDNs involved

S‐0‐0130 [

}

 104], S‐0‐0170 [

}

 124]S‐0‐0179 [

}

 125], S‐0‐0305 [

}

 156], S‐0‐0405 [

}

 173]

Note

Additional functional description

AX5000 / Probe unit

Single mode

S­0­0409 Probe 1 positive latched / Single mode

Format

Size in bit

Offset

Properties

Enum

16

0

­­­

AX5000 ­ IDN­Descriptions

174

Version 3.1