S-0-0044 velocity data scaling type, S‐0‐0044 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 47

Advertising
background image

S­IDNs

S­0­0044 Velocity data scaling type

This parameter defines the scaling of the velocity values. This scaling can currently not be changed. The
controller can read the scaling and adjust the set value specification and the actual value processing.

Attributes

Name

Value

Format

Binary

Data length

16

Decimal point

0

Min value

­

Max value

­

Default value

10

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Bit pattern:

Bit Meaning

0­2 Scaling method

Scaling method

0 = no scaling
1 = linear
2 = rotary

3

Scaling type
Scaling type

0 = preferred scaling 
1 = parameter scaling

4

Units for linear / rotational scaling
Units for linear / rotational scaling

0 = metre [m] or revolution [rev]
1 = inch [in]

5

Time units
Time units

0 = minute [min]
1 = second [s]

6

Data reference
Data reference

0 = at the motor shaft
1 = at the load

7 ­

15

Reserved

Note

IDNs involved

S‐0‐0045 [

}

 48]S‐0‐0046 [

}

 49]

AX5000 ­ IDN­Descriptions

47