S-0-0189 following distance, S‐0‐0189 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 131

Advertising
background image

S­IDNs

S­0­0189 Following distance

The parameter contains the position lag, i.e. the current difference between the position command value
(S­0­0047) and the position feedback value. Depending on the current operating mode, the position
feedback value 1 (S­0­0051) or 2 (S­0­0053) is used.

Attributes

Name

Value

Format

dec

Data length

32

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

inc

Changeable in EtherCAT state

No

Cyclic transfer

AT

Device parameter

No

Related to interface revision

No

Position lag = position command value ­ position feedback value

Note

IDNs involved

S‐0‐0051 [

}

 52]S‐0‐0053 [

}

 53], S‐0‐0047 [

}

 50], S‐0‐0076 [

}

 55], S‐0‐0079 [

}

 57],

AX5000 ­ IDN­Descriptions

131

Version 3.1

Advertising