S­0­0080 Torque command value

The parameter contains the torque/force set value. If the drive is in mode "Torque control", the drive attempts
to generate this torque/force at the motor shaft.

Attributes

Name

Value

Format

dec

Data length

16

Decimal point

1

Min value

­100.0

Max value

100.0

Default value

­

Unit

%

Changeable in EtherCAT state

No

Cyclic transfer

MDT

Device parameter

No

Related to interface revision

No

If the drive is operated in mode "Torque control", there is no velocity control in the drive. In this case the drive
velocity must be monitored and controlled by the controller. The base for the percentage figure is P­0­0092.
Saturation is compensated by P­0­0074.

Note

IDNs involved

S‐0‐0085 [

}

 65]S‐0‐0086 [

}

 66], P­0­0092

AX5000 ­ IDN­Descriptions