S-0-0188 idn-list of configurable data in the mdt, Actual length, Max length – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 130: All operation data, S‐0‐0188

Advertising
background image

S­IDNs

S­0­0188 IDN­list of configurable data in the MDT

The parameter contains a list of parameters whose data can be processed cyclically by the drive as set
values.

Attributes

Name

Value

Format

idn

Data length

12064

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

The AX5000 allows the telegram type "application telegram" in S­0­0015 and therefore supports this list.

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDNs involved

S‐0‐0015 [

}

 17]

Actual length

S­0­0188­IDN­list of configurable Data in the MDT / Actual length

Format

Size in bit

Offset

Properties

UINT

16

0

­­­

Max length

S­0­0188­IDN­list of configurable Data in the MDT / Max length

Format

Size in bit

Offset

Properties

UINT

16

16

­­­

All operation data

S­0­0188­IDN­list of configurable Data in the MDT / All operation data

Format

Size in bit

Offset

Properties

12032

32

­­­

AX5000 ­ IDN­Descriptions

130

Version 3.1

Advertising