S­IDNs

Bit Meaning

15 Drive On/Off 

Drive On/Off 
0 = drive off: Once bit 15 was reset by S­0­0134, the maximum drive off delay time is started. Once the
maximum drive off delay time has elapsed, "locking of the brake" is initiated and "torque" is disabled,
regardless of the current motor speed (S­0­0273).
1 = drive on

Note

IDNs involved

S‐0‐0099 [

}

 73]

AX5000 ­ IDN­Descriptions