BECKHOFF AX5000 S-IDN Parameters User Manual
Page 107
Advertising
![background image](/files/774936/content/doc107.png)
SIDNs
Bit Meaning
15 Drive On/Off
Drive On/Off
0 = drive off: Once bit 15 was reset by S00134, the maximum drive off delay time is started. Once the
maximum drive off delay time has elapsed, "locking of the brake" is initiated and "torque" is disabled,
regardless of the current motor speed (S00273).
1 = drive on
Note
IDNs involved
AX5000 IDNDescriptions
107
Version 3.1