SIDNs
S00099 Reset class 1 diagnostic (pc)
This parameter contains the SoE command that can be used to execute a drive reset. The reset attempts to
acknowledge the C1D errors of the drive.
Attributes
Name
Value
Format
binary
Data length
16
Decimal point
0
Min value
Max value
Default value
Unit
Changeable in EtherCAT state
PreOp, SafeOp and Op
Cyclic transfer
No
Device parameter
No
Related to interface revision
No
Bit pattern:
Bit Meaning
0
Cancel cmd
Cancel command
0 = disable
1 = enable
1
Set cmd
Set command
0 = disable
1 = enable
2
Reserved
3
Set & enable command
Set & enable command
0 = disable
1 = enable
4
15
Reserved
Note