S­IDNs

S­0­0022 IDN­list of invalid operation data for CP3
(SafeOp)

The parameter contains a list of parameters that are contained in S­0­0019, and which the drive has
detected as invalid before switching from SafeOp to Op.

Attributes

Name

Value

Format

idn

Data length

192

Decimal point

0

Min value

­

Max value

­

Default value

­

Unit

­

Changeable in EtherCAT state

No

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

If switching in CP3 is error­free, the list S­0­0022 is empty. If invalid parameters or invalid parameter
combinations are detected during switching, S­0­0022 contains the numbers of the invalid parameters, and
the switching is acknowledged with an error. Switching takes place via the AL Control and AL Status
Register of the EtherCAT SlaveController.

Note

Nested structure

Note the nesting depth and the structure information at the start of the descriptions.

Note

IDNs involved

S‐0‐0019 [

}

 21]

Actual length

S­0­0022­IDN­list of invalid operation data for CP3 / Actual length

Format

Size in bit

Offset

Properties

UINT

16

0

­­­

Max length

S­0­0021­IDN­list of invalid operation data for CP3 / Max length

Format

Size in bit

Offset

Properties

UINT

16

16

­­­

AX5000 ­ IDN­Descriptions