Boonton 4500B RF Peak Power Analyzer

Remote Operation

5-22


DISPlay:CHANnel: MIDdle: LEFT

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Middle row,
Left

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel: MIDdle:LEFT <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:CHANnel: MIDdle:MIDdle

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Middle row,
Middle

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel: MIDdle: MIDdle <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.



DISPlay:CHANnel: MIDdle:RIGHt

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Middle row,
Right

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel: MIDdle: RIGHt <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.



DISPlay:CHANnel:TOP:LEFT

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Top row, Left
column of the nine element parameter field above the trace box. DISPlay:PARAmeter:MODE
must be set to MEAS.

Syntax:

DISPlay:CHANnel:TOP:LEFT <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.