Display:channel:top: middle, Display:channel:top: right, Display:parameter:bottom:left – Boonton 4500B Peak Power Meter User Manual

Page 223: Display:parameter:bottom:middle, Display:channel:top: middle -23, Display:channel:top: right -23, Display:parameter:bottom:left -23, Display:parameter:bottom:middle -23, Boonton 4500b rf peak power analyzer, Remote operation

Advertising
background image

Boonton 4500B RF Peak Power Analyzer

Remote Operation

5-23

DISPlay:CHANnel:TOP: MIDdle

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Top row,
Middle

column

of

the

nine

element

parameter

field

above

the

trace

box.

DISPlay:PARAmeter:MODE must be set to MEAS.

Syntax:

DISPlay:CHANnel:TOP: MIDdle <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:CHANnel:TOP: RIGHt

Description:

Set or return the channel for the auto-measure or fixed parameter displayed in the Top row, Right
column of the nine element parameter field above the trace box. DISPlay:PARAmeter:MODE
must be set to MEAS.

Syntax:

DISPlay:CHANnel:TOP: RIGHt <asc>

Argument:

<asc> = {CH1, CH2, TRIG1, TRIG2, CHM, MEM1, MEM2}

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:PARAmeter:BOTtom:LEFT

Description:

Set or return the auto-measure or fixed parameter displayed in the Bottom row, Left column of the
nine element parameter field above the trace box. The selected parameter will be for the currently
active channel. See DISPlay:ACTive command. DISPlay:PARAmeter:MODE must be set to
MEAS.

Syntax:

DISPlay:PARAmeter:BOTtom:LEFT <asc>

Argument:

See Display Parameter Table below

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.

DISPlay:PARAmeter:BOTtom:MIDdle

Description:

Set or return the auto-measure or fixed parameter displayed in the Bottom row, Middle column of
the nine element parameter field above the trace box. The selected parameter will be for the
currently active channel. See DISPlay:ACTive command. DISPlay:PARAmeter:MODE must be
set to MEAS.

Syntax:

DISPlay:PARAmeter:BOTtom:MIDdle <asc>

Argument:

See Display Parameter Table below

Valid Modes:

Pulse Mode only. Note: Modulated mode does not display Status and Measurement parameters.
Statistical mode displays a fixed combination of status and auto-measure parameters.