112

ingress broadcast
frames. These
options are
equivalent.

bplimit

Specifies the number of cells for back pressure.
A cell represents 128 bytes. The range is 1 to
57,344 cells. The default value is 8192 cells.

description

A description for the port, from 1 to 15
alphanumeric characters. Spaces are allowed
but do not use special characters.

fctrllimit

Specifies the number of cells for flow control. A
cell represents 128 bytes. The range is 1 to
7935 cells. The default value is 7935 cells.

flowcontrol

Specifies the flow control on the port. Flow
control applies only to ports operating in full
duplex mode. When flow control is activated, a
port sends out a PAUSE packet whenever it
wants the end node to stop sending packets.
The options are:

disabled No flow control. This is the default

setting.

enabled

Flow control is activated.

holbplimit

Specifies the threshold at which the switch
signals a head of line blocking event on a port.
The threshold is specified in cells. A cell is 128
bytes. The range is 1 to 61,440 cells; the default
is 7,168.

mdimode

Sets the wiring configuration of the port. This

parameter applies only to twisted pair ports, and
only when a port’s speed and duplex mode are
set manually. If a port is autonegotiating its
speed and duplex mode, the MDI/MDIX setting
is established automatically and cannot be
changed. The options are:

mdi

Sets the port’s configuration to MDI.

mdix Sets the port’s configuration to MDI-X.

overridepriority

Determines if a port should ignore the priority
level in tagged packets and store the packets in
the egress port’s priority queue that corresponds
to the priority level set with the PRIORITY

Advertising