AT-S63 Management Software Menus Interface User’s Guide

Section I: Basic Features

265

packets with the new value specified
with the PRIORITY parameter.

no, off, false

Does not replace the user priority value

in the packets with the new value
specified in with the PRIORITY
parameter. This is the default.

classifierlist

Specifies the classifiers to be assigned to the flow
group. The specified classifiers replace any classifiers
already assigned to the flow group. Separate multiple
classifiers with commas (e.g., 4,7,8). The classifiers
must already exist. The NONE options removes all
classifiers currently assigned to the flow group without
assigning any new ones. To add classifiers without
replacing those already assigned, see “ADD QOS
FLOWGROUP” on page 242.

Description

This command modifies the specifications of an existing flow group. The
only parameter you cannot change is a flow group’s ID number. To initially
create a flow group, refer to “CREATE QOS FLOWGROUP” on page 245.

Note

For examples of command sequences used to create entire QoS
policies, refer to “CREATE QOS POLICY” on page 247.

When modifying a flow group, note the following:

ˆ

You cannot change a flow group’s ID number.

ˆ

Specifying an invalid value for a parameter that already has a value
causes the parameter to revert to its default value.

Examples

This command changes the user priority value to 6 in flow group 15:

set qos flowgroup=15

priority=

6

This command assigns classifiers 23 and 41 to flow group 25. Any
classifiers already assigned to the flow group are replaced:

set qos flowgroup=25

classifierlist=23,41

This command returns the MARKVALUE setting in flow group 41 back to
the default setting of NONE. At this setting, the flow group will not
overwrite the ToS setting in the packets: