severity

Saves events of a particular severity.
Choices are I for Informational, E for Error,
W for Warning, and D for Debug. You can
select more than one severity at a time (for
example, E,W). For a definition of the
severity levels, see Table 5, “Event Log
Severity Levels” on page 204.

overwrite

Overwrites the file if it already exists. Without this

option, the command displays an error if the file
already exists.

Description

This command saves the current entries in the event log to a file in the file
system. The parameters in the command allow you to specify which
events you want saved in the log file.

Examples

The following command saves all informational, error, and warning

messages stored in the permanent event log in a file called “switch2.log”:

save log=permanent filename=switch2.log

The following command saves the error messages of the VLAN module

stored in the temporary event log in a file called “sw14.log.”:

save log=temporary filename=sw14.log module=vlan severity=e

The following command saves all informational messages in a file called

“sw56.log” and overwrites the file of the same name if it already exists in
the file system:

save log=permanent filename=sw56.log severity=i overwrite