Examples – Allied Telesis AT-S63 User Manual

Page 445

Advertising
background image

AT-S63 Management Software Command Line Interface User’s Guide

445

Note the following before using this command:

ˆ

You must first create the protected ports VLAN by giving it a name and
a VID before you can add ports. Creating a VLAN is accomplished with
“CREATE VLAN PORTPROTECTED” on page 446.

ˆ

Both command syntaxes perform the same function. The difference is
that with syntax 1 you can add ports of only one type, tagged or
untagged, at a time. With syntax 2, you can add both at the same time.

ˆ

If you are adding an untagged port to a group, the port cannot be an
untagged member of another protected port VLAN. It must be an
untagged member of the Default_VLAN or a port-based or tagged
VLAN. To remove a port from a protected port VLAN, use “DELETE
VLAN” on page 447.

ˆ

You cannot add a new uplink port to a VLAN if the VLAN has already
been assigned an uplink port. Instead, you must delete the existing
uplink port(s) using the “DELETE VLAN” on page 447 and then re-add
the uplink port(s) using this command.

ˆ

You cannot add ports to an existing group. To modify an existing group,
you must delete the group by removing all ports from it, using
“DELETE VLAN” on page 447, and then add the ports back to the
group using this command.

Examples

The following command uses Syntax 1 to specify that port 11 is to be an
untagged uplink port for the protected ports VLAN called InternetGroups:

add vlan=InternetGroups ports=11 frame=untagged group=uplink

The following command accomplishes the same thing using Syntax 2:

add vlan=InternetGroups untaggedports=11 group=uplink

The following command uses Syntax 1 to create group 4 in the
InternetGroups VLAN. The group will consist of two untagged ports, 5 and
6:

add vlan=InternetGroups port=5,6 frame=untagged group=4

The following command does the same thing using Syntax 2:

add vlan=InternetGroups untaggedports=5,6 group=4

Advertising