Modifying the event log full action – Allied Telesis AT-S63 User Manual

Page 237

Advertising
background image

AT-S63 Management Software Menus Interface User’s Guide

Section II: Advanced Operations

237

In addition to the information displayed in Normal mode, the Full mode
also displays additional columns in the table, as described below:

Event ID
A unique, random number assigned to each event.

Source File:Line Number
The AT-S63 software source file name and the line number in that
source file that produced the event.

10. Type the following to scroll through the event log:

ˆ

P - Previous page

ˆ

N - Next page

ˆ

F - First page

ˆ

L - Last page

To clear the current event log, go to “Clearing an Event Log” on
page 238.

Modifying the

Event Log Full

Action

To modify the action taken when the event log becomes full, perform the
following procedure:

1. From the Main Menu, type 5 to select System Administration.

The System Administration menu is shown in Figure 4 on page 46.

2. From the System Administration menu, type 8 to select Event Log.

The Event Log menu is shown in Figure 72 on page 231.

3. From the Event Log menu, type 2 to select Modify Log Output.

Note

This selection applies only to the default event logs, 0 and 1.

The following prompt is displayed:

Enter output ID to modify [0 to 20] ->

4. Type 0 to select the permanent log, or 1 to select the temporary log.

The following prompt is displayed:

Enter new log full action (1-Wrap on Full, 2-Halt on
Full) ->

5. Make a selection from the following options:

Advertising