Chapter 23: Port-based and Tagged VLANs

564

Section V: VLANs

You can specify the ports individually (e.g., 2,3,5), as a range (e.g., 7-
9), or both (e.g., 2,5,7-9).

9. Type 4 to select Untagged Ports and specify the ports on the switch to

function as untagged ports in the VLAN. If this VLAN will not contain
any untagged ports, leave this field empty.

You can specify the ports individually (e.g., 2,3,5), as a range (e.g., 7-
9), or both (e.g., 2,5,7-9).

10. Type C to select Create VLAN.

The following message is displayed:

SUCCESS - Press any key to continue.

The AT-S63 management software creates the new VLAN. The new
VLAN is now ready for network use.

11. Press any key.

The VLAN Configuration menu in Figure 198 on page 561 is
redisplayed.

12. To verify that the VLAN was created correctly, type 6 to select Show

VLANs.

13. Check to see that the VLAN contains the appropriate ports.

14. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.

15. Repeat this procedure to create additional VLANs.

Note

When you create a new VLAN, ports designated as untagged ports
of the new VLAN are automatically removed from their current
untagged VLAN assignment. For example, if you are creating a new
VLAN on a switch that contains only the Default_VLAN, the ports
that you specify as untagged ports of the new VLAN are
automatically removed from the Default_VLAN.

Tagged ports are not removed from any current VLAN assignments
because tagged ports can belong to more than one VLAN at a time.