Chapter 20: SNMPv3

440

Section III: SNMPv3

7. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.

Modifying the Storage Type

To modify the Storage Type parameter in an SNMPv3 Target Address
Table entry, perform the following procedure.

1. Follow steps 1 through 5 in the procedure described in “Creating an

SNMPv3 User Table Entry” on page 380. Or, from the Main Menu type
5->1->1->8->5.

The Configure SNMPv3 Table menu is shown in Figure 139 on page
381.

2. From the Configure SNMPv3 Table menu, type 7 to select Configure

SNMPv3 Target Address Table.

The Configure SNMPv3 Target Address Table menu is shown in
Figure 150 on page 430.

3. From the Configure SNMPv3 Target Address Table menu, type 3 to

select Modify SNMPv3 Table Entry.

The Modify SNMPv3 Target Address Table menu is shown in Figure
151 on page 434.

4. To modify the Storage Type, type 7 to select Set Storage Type.

The following prompt is displayed:

Enter Target Address Name:

5. Enter a previously configured Target Address Name.

This is the name of the SNMP manager, or host, that manages the
SNMP activity on your switch. You can enter a name of up to 32
alphanumeric characters.

The following prompt is displayed:

Enter Storage Type [V-Volatile, N-NonVolatile]:

6. Select one of the following storage types for this table entry:

V - Volatile
Select this storage type if you do not want the ability to save an entry in
the SNMPv3 Target Address Table to the configuration file. After
making changes to an SNMPv3 Target Address Table entry with a
Volatile storage type, the S - Save Configuration Changes option does
not appear on the Main Menu.