Modifying a storage type – Allied Telesis AT-S63 User Manual

Page 397

Advertising
background image

AT-S63 Management Software Menus Interface User’s Guide

Section III: SNMPv3

397

The following prompt is displayed:

Enter View Subtree (OID format/Text Name):

6. Enter the View Subtree value for this View Name.

You can enter either a numeric value in hex format or the equivalent
text name. For example, the OID hex format for TCP/IP is:

1.3.6.1.2.1.6

The text format is for TCP/IP is:

tcp

The following prompt is displayed:

Enter View Type [I-Included, E-Excluded]:

7. Choose one of the following view types:

I - Included
Enter this value to permit the View Name to see the subtree specified
above.

E - Excluded
Enter this value to not permit the View Name to see the subtree
specified above.

8. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.

Modifying a Storage Type

To modify the Storage Type parameter in an SNMPv3 View Table entry,
perform the following procedure.

1. Follow steps 1 through 5 in the procedure described in “Creating an

SNMPv3 User Table Entry” on page 380. Or, from the Main Menu type
5->1->1->8->5.

The Configure SNMPv3 Table menu is shown in Figure 139 on page
381
.

2. From the Configure SNMPv3 Table menu, type 3 to select Configure

SNMPv3 View Table.

The Configure SNMPv3 View Table menu is shown in Figure 142 on
page 391.

3. From the Configure SNMPv3 View Table menu, type 3 to select Modify

SNMPv3 Table Entry.