AT-S63 Management Software Menus Interface User’s Guide

Section IV: Port Security

679

5. Enter the number of the port on the switch where you want to assign

the static address. If you are adding a static unicast address, you can
specify only one port.

If you are entering a static multicast address, you must specify the port
when the multicast application is located as well as the ports where the
host nodes are connected. Assigning the address only to the port
where the multicast application is located will result in the failure of the
multicast packets to be properly forwarded to the host nodes. You can
specify the ports individually (e.g., 1,4,5), as a range (e.g., 11-14) or
both (e.g., 15-17,22,24).

The following prompt is displayed:

Please enter VLAN ID: [1 to 4094] -> 1

6. Enter the VLAN ID where the port is a member.

7. Repeat this procedure starting with Step 3 to enter additional static

unicast or multicast MAC addresses.