Modifying the storage type – Allied Telesis AT-S63 User Manual

Page 420

Advertising
background image

Chapter 20: SNMPv3

420

Section III: SNMPv3

3-v3
Select this value to associate the User Name with the SNMPv3
protocol.

The following prompt is displayed:

Enter Group Name:

7. Enter the new Group Name.

This value must match a value configured in the Group Name
parameter in the Configure SNMPv3 Access Table. See “Creating an
SNMPv3 Access Table Entry” on page 399.

8. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.

Modifying the Storage Type

To modify the Storage Type in an SNMPv3 SecurityToGroup Table entry,
perform the following procedure.

1. Follow steps 1 through 5 in the procedure described in “Creating an

SNMPv3 User Table Entry” on page 380. Or, from the Main Menu type
5->1->1->8->5.

The Configure SNMPv3 Table menu is shown in Figure 139 on page
381.

2. From the Configure SNMPv3 Table menu, type 5 to select Configure

SNMPv3 SecurityToGroup Table.

The Configure SNMPv3 SecurityToGroup Table is shown in Figure 144
on page 400.

3. From the Configure SNMPv3 SecurityToGroup Table, type 3 to select

Modify SNMPv3 Table Entry.

4. To modify the storage type, type 2 to select Set Storage Type.

The following prompt is displayed:

Enter User (Security) Name:

5. Enter a User Name.

The User Name must be previously configured in the Configure
SNMPv3 User Table menu. See “Creating an SNMPv3 User Table
Entry” on page 380.

The following prompt is displayed:

Enter Security Model [1-v1, 2-v2c, 3-v3]: