Chapter 20: SNMPv3

428

Section III: SNMPv3

1. Follow steps 1 through 5 in the procedure described in “Creating an

SNMPv3 User Table Entry” on page 380. Or, from the Main Menu type
5->1->1->8->5.

The Configure SNMPv3 Table menu is shown in Figure 139 on page
381.

2. From the Configure SNMPv3 Table menu, type 6 to select Configure

SNMPv3 Notify Table.

The Configure SNMPv3 Notify Table menu is shown in Figure 148 on
page 423.

3. From the Configure SNMPv3 Notify Table menu, type 3 to select Modify

SNMPv3 Table Entry.

The Modify SNMPv3 Notify Table is shown in Figure 149 on page 426.

4. To modify the Storage Type, type 3 to select Set Storage Type.

The following prompt is displayed:

Enter Notify Name:

5. Enter a Notify Name.

The following prompt is displayed:

Enter Storage type [V-Volatile, N-NonVolatile]:

6. Select one of the following storage types for this table entry:

V - Volatile
Select this storage type if you do not want the ability to save an entry in
the SNMPv3 Notify Table to the configuration file. After making
changes to an SNMPv3 Notify Table entry with a Volatile storage type,
the
S - Save Configuration Changes option does not appear on the Main
Menu.

N-NonVolatile
Select this storage type if you want the ability to save an entry in the
SNMPv3 Notify Table to the configuration file. After making changes to
an SNMPv3 Notify Table entry with a NonVolatile storage type, the S -
Save Configuration Changes option appears on the Main Menu,
allowing you to save your changes. Allied Telesyn recommends this
storage type.

7. After making changes, type R until you return to the Main Menu. Then

type S to select Save Configuration Changes.