Allied Telesis AT-S63 User Manual

Page 316

Advertising
background image

Chapter 16: Quality of Service

316

Section II: Advanced Operations

The Flow Group Configuration menu is shown in Figure 109 on page
314.

4. From the Flow Group Configuration menu, type 2 to select Modify Flow

Group.

The following prompt is displayed:

Available Flow Group(s): 0-10
Enter Flow Group ID : [0 to 1023] -> 0

5. Enter the ID number of the flow group you want to modify. You can

modify only one flow group at a time.

The Modify Flow Group menu is shown in Figure 111.

Figure 111. Modify Flow Group Menu

6. Modify the settings as needed.

When you modify a flow group, note the following:

ˆ

You cannot change the flow group ID number.

ˆ

To delete a value from a variable so as to leave it blank, select the
variable and then use the backspace key to delete its default
value.

ˆ

Specifying an invalid value for a parameter that already has a
value causes the parameter to revert to its default value.

7. Type M to select Modify Flow Group.

8. To modify another flow group, repeat this procedure starting with step

4. To assign the flow group to a traffic class, go to “Managing Traffic
Classes” on page 320.

Allied Telesyn Ethernet Switch AT-94xx - AT-S63

Marketing

User: Manager

11:20:02 02-Mar-2005

Modify Flow Group

1 - Flow Group ID .............. 2
2 - Description ................ Video1
3 - DSCP value ................. 0
4 - Priority ................... 6
5 - Remark Priority ............ No
6 - Classifier List ............ 11

M - Modify Flow Group
R - Return to Previous Menu

Enter your selection?