Operation – Barco DX-700 User Manual

Page 116

Advertising
background image

116

DX-700 • User’s Guide • Rev 02

4. Operation

Using the Input Management Menu

5.

Press {EDID} to display the EDID Menu, a sample of which is shown below. The
selected input connector’s current EDID format is shown above the format list.

Figure 4-50.

Input Management Menu: EDID Menu (sample)

Extended Display Identification Data (EDID) is a VESA standard data format that
contains information about a display device and its resolution, both preferred and
allowed. Each input module contains two EDID files (one for digital, one for
analog), which are both stored in the module’s non-volatile memory. These EDID
files may be read by an external computer’s graphics card when the computer’s
output is connected to DX-700 via the DVI-I or HD-15 connector during boot-up.

6.

To change EDID, select a format from the list and press {Apply}. The new values
are stored in the input module’s non-volatile memory.

7.

Press {Previous} to return to Image Processing Tab 1.

Note

The above procedure sets EDID for an active input. To set
EDID for any DVI-I or HD-15 input connector (even ones that
have not been set up), use the DX-700 Management Menu.
Refer to the “

Using the EDID Menu

section on page 151.

Advertising