DX-700 • User’s Guide • Rev 02

4. Operation

Using the Input Management Menu

4.

Select the Input Timing Tab (I.T.) to display input timing parameters.

Figure 4-57.

Input Management Menu: Input Timing Tab (sample)

5.

Perform the following adjustments as required:

a.

Use the Pixel Phase slider to select where pixels are sampled (ideally,
on the pixel’s peak). For optimum visual results when adjusting high-
resolution sources, project a burst test pattern and adjust the sampling
for the minimum noise.

b.

Use the Input H Total slider to set the total pixel count per line.

c.

Use the Input H Position slider to set the start of the active area’s
horizontal offset from H sync.

d.

Use the Input H Active slider to set the active H region.

e.

Use the Input V Position slider to set the start of the active area’s
vertical offset from V sync.

f.

Use the Input V Active slider to set the active V region.

This completes the Input Timing adjustment procedure.