Device Parameters at lower portion of screen

Physical Offset Maintain an offset of zero if the sensor is

installed at the bottom center of the pipe. If it is installed up
the side of the pipe, enter the vertical distance from the bottom
center of the pipe to the height at which the nose of the sensor
exists. The simplest way to obtain this value is to measure the
depth of the flow, measure the distance from the nose of the
sensor to the flow surface, and then subtract the second
measurement from the first.

Pipe Height This field displays the pipe height at the

monitoring point where the combo sensor is installed. This
value is entered through the Installation Generator and used
when calculating the depth of the flow.

Channel Select the channel number of the port on the top of

the monitor to which the combo sensor device is attached.