ADS Environmental Services Profile Software 950015B6 User Manual

Page 451

Advertising
background image

12-18 Profile Software User's Guide

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

3. Select one or both of the following:

Select the Display checkbox in the Current section of the
tab to display a Colebrook-White curve based on the
current roughness and slope factors from the database
(select this only if valid roughness and slope values display
in the Roughness and Slope fields).

Select the Generate and Display checkboxes in the
Calculated section of the tab to generate and display a
Colebrook-White curve based on calculated Roughness
and Slope factors for the current scattergraph data.

4. Select OK to generate and display the curve(s).

Store Calculated Roughness and Slope Values
(optional
)

If you generated a Calculated Colebrook-White curve you can
store the new roughness and slope values to the database. After the
Calculated Colebrook-White curve generates, perform the
following steps to review and store the Calculated roughness and
slope values:

Curve
Properties
button

1. Select the Edit > Curve Properties option or the Curve

Properties toolbar button.

2. Select the Colebrook-White tab.

3. The roughness and slope values display in the Calculated

section of the screen. Select the Store button to save the new
roughness and slope values to use with future data. Store
allows you to define the time period to begin applying the new
values.

Advertising