Profile Main Screen

2-81

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

weir to measure overflows that may experience of river
intrusion.

Maximum Velocity Select the maximum expected velocity

that will occur at the site for the monitor to use in fine-tuning
the velocity data. The default setting (Auto) serves to
optimize the range and resolution of the velocity data samples
to match the characteristics of the flow.

Transmit Frequency Select the frequency at which to

transmit the signal. ADS recommends leaving the default
setting (Normal) for most applications. However, if hydraulic
conditions at the site are resulting in questionable or erroneous
readings, consider applying the other frequency option.

Gain This read-only value represents the factor applied to

raw velocity readings to determine average velocity for
calculating quantity and typical days in the monitor. The
Gain is not applied to velocity readings reported in
Diagnostics where raw velocity readings are reported for
comparison to manual measurements.

Cross Check Gain Enter the value by which to multiply

raw velocity readings in the monitor to determine average
velocity for calculating CROSS_VELOCITY events in the
monitor.

Store Data Select this checkbox to ensure the monitor logs

the velocity data to memory. This option is selected by
default.

Advanced Select this button to access the Advanced

Parameters window.