from the nose of the sensor to the manhole invert (or
bottom).

Electronic Offset Enter the difference that exists between

the pressure depths sensor readings and the manually
measured depth. Profile will apply this value to each pressure
reading to accurately calculate depth. (This applies only to
pressure sensors associated with FlowShark, IS FlowShark,
and FlowAlert monitors.)

Edit Pressure Parameters (FlowAlert)

Note: The remaining parameters concerning, Depth
Alarms
and Readings To Average apply only to pressure
devices assigned to FlowAlert monitors.

Depth Alarms - High Edit this device to ensure the

monitor initiates a high depth alarm when a pressure depth
reading reaches or exceeds a specified depth in the following
way:

Enable Select this checkbox to enable the high depth
alarm options and to activate the high depth alarm when
the appropriate conditions are satisfied. When the High