6-52

Profile Software User's Guide

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

DOF/+/- Enter the manually measured distance from the

flow surface to the bottom of the pipe and the estimated +/-
deviation.

Air DOF/ +/- Enter the manually measured distance from the

face of the ultrasonic depth sensor or top of the pipe to the
flow surface and any estimated +/- deviation. Select the point
of reference, Face of Bat or Crown of Pipe, to where the
technician took the Air DOF measurement from the
corresponding drop-down list.

DOF Type to Use Select the manual flow depth

measurement (DOF or Air DOF) you want Profile to
compare with the monitor readings.

The Calculated DOF From Air DOF field displays the flow depth
based on the pipe height, physical offset, and manual air DOF
measurement, compensating for the selected point of reference of the
air DOF (Face of Bat (sensor) or Crown of Pipe).

Silt Enter the depth of the debris at the bottom of the pipe at

the monitoring point and the estimated deviation.

Velocity Enter the peak velocity value as manually

measured in the field.

V-meter No. Enter the identification number corresponding

the velocity meter being used for the manual field
measurements and then identify the type of velocity meter
being using from the drop-down list. Choose from Magnetic,
Propeller, or FS-HV (FlowShark HV).

Fan No. Enter the fan identification number corresponding

to the Propeller type velocity sensor, if applicable.

Body No. Enter the body identification number

corresponding to the Propeller type velocity sensor, if
applicable.

The Review Depth Confirmation dialog displays.