Profile Main Screen

2-107

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

difference, the monitor will flag the pair and remove it from
the calculation. The monitor will average the remaining pairs
to calculate the depth readings. Profile default to 0.4 inches.

Scrubbing Algorithm Select the scrubbing algorithm you

want the monitor to apply when processing ultrasonic depth,
Smart Depth, or pressure depth to determine AVGUDEPTH.

Average-Depth Bias Selecting this option ensures the
monitor excludes unusual spikes or drops that may exist in
the depth readings when calculating AVGUDEPTH.
Spikes and drops represent isolated, inconsistently high
(spikes) or low (drops) depth readings that fall outside a
predefined tolerance or range. Profile defaults to this
option.

Low-Depth Bias Selecting this option ensures the
monitor excludes unusual spikes that may exist in the depth
readings when calculating AVGUDEPTH.

High-Depth Bias Selecting this option ensures the
monitor excludes unusual drops that may exist in the depth
readings when calculating AVGUDEPTH.

Store Data Select this checkbox to ensure the monitor logs

the ultrasonic data. The monitor logs this data by default
(selected). You must deselect this checkbox if you do not
want the monitor to log the ultrasonic data.