Diagnostics

6-67

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 - 2012 ADS LLC. All Rights Reserved.

Air DOF Enter the manually measured distance from the

face of the ultrasonic depth sensor or top of the pipe to the
flow surface and any estimated deviation. Select the point of
reference at the top of the pipe from which the technician took
the Air DOF measurement from the corresponding drop-down
list.

The Calculated DOF From Air DOF field displays the flow depth
based on the pipe height, physical offset, and manual air DOF
measurement, compensating for the selected point of reference of the
air DOF (Face of Bat (sensor) or Crown of Pipe).

DOF Type to Use Select the manual flow depth

measurement (DOF or Air DOF) you want Profile to
compare with the monitor readings.

Silt Enter the depth of the debris at the bottom of the pipe at

the monitoring point and the estimated deviation.

Velocity Enter the velocity of the flow obtained at the

monitoring point manually using a portable velocity meter.

V-meter No. Enter the serial number of the portable

velocity meter used to obtain the manual measurements.

Fan No. (applies only to propeller-type velocity meters)

Enter the fan number of the portable velocity meter used to
obtain the manual measurements.

Body No. (applies only to propeller-type velocity meters)

Enter the body number of the portable velocity meter used to
obtain the manual measurements.

Repeat these instructions for a second manual velocity
measurement, when applicable.

The Enter Velocity Profile dialog displays.